How to Fix CVE-2025-2775: XXE Vulnerability in SysAid On-Prem
Related fixes
Other vulnerabilities in the same area that are worth patching alongside this one:
- How to Fix CVE-2025-58360: XXE Injection in Geoserver geoserver — XXE Injection in Geoserver geoserver
- How to Fix CVE-2025-23311: Triton Inference Server (Bundle Sibling) — Triton Inference Server (Bundle Sibling)
- How to Fix CVE-2025-64328: Command Injection in filestore , Command Injection in filestore
- How to Fix CVE-2025-47827: Security Vulnerability in In IGEL OS , Security Vulnerability in In IGEL OS
- How to Fix CVE-2025-49220: Trend Micro Apex Central (Bundle Sibling) , Trend Micro Apex Central (Bundle Sibling)
*By Sai Kiran Pandrala*
| Severity | CVSS 9.3 - Critical |
|---|---|
| Actively exploited? | Yes, listed in CISA KEV (added 2025-07-22) |
| Affected | 0 <= 23.3.40 |
| Fixed in | See vendor advisory |
| Type (CWE) | CWE-611: Improper Restriction of XML External Entity Reference |
Patch immediately. CISA's KEV listing means active exploitation is confirmed. Federal agencies must remediate by 2025-08-12.
What is CVE-2025-2775?
CVE-2025-2775 is an XML external entity (XXE) flaw in SysAid On-Prem. The XML parser resolves external entities, which lets an attacker read files on the server or trigger server-side requests. Vendor description: SysAid On-Prem versions <= 23.3.40 are vulnerable to an unauthenticated XML External Entity (XXE) vulnerability in the Checkin processing functionality, allowing for administrator account takeover and file read primitives.
Why this CVE matters
XXE vulnerabilities convert a simple XML parsing endpoint into a file-read and server-side request forgery primitive. The chained impact is often cloud-metadata theft or internal service enumeration from inside the target's network.
For deployments of SysAid On-Prem that have been exposed to the public internet during the disclosure window, the operating assumption should be that scanning has already happened. Confirmed in-the-wild exploitation makes that assumption mandatory, not cautious. Patching closes the door; log review and credential rotation close out the rest of the response.
Am I affected?
You are affected if your installation matches any of these version ranges:
- SysAid On-Prem: 0 <= 23.3.40
Check your installed version against the list above. If you cannot determine the version, treat the system as affected and follow the upgrade path below.
Open SysAid On-Prem's About dialog or run the vendor-documented version-check command. Compare the result against the affected ranges in the advisory.
How to fix CVE-2025-2775
- Read the vendor advisory in full: https://documentation.sysaid.com/docs/24-40-60
- Upgrade SysAid On-Prem to the patched build listed in the vendor advisory.
- Back up the configuration (and database, where applicable) before upgrading.
- Apply the patch in a maintenance window. For HA pairs, upgrade the standby node first, fail over, then upgrade the former primary.
- Restart the affected service so the patched binary loads, then verify the new version (see verification section).
Patch via your OS package manager
# The exact package name and patched version are listed in the vendor advisory:
# https://documentation.sysaid.com/docs/24-40-60
# Debian / Ubuntu
sudo apt update
sudo apt install --only-upgrade sysaidon-prem
# RHEL / Rocky / AlmaLinux / Fedora
sudo dnf upgrade sysaidon-prem
# openSUSE
sudo zypper update sysaidon-prem
# Verify the running version matches the fixed version
dpkg -s sysaidon-prem 2>/dev/null | grep -i version || rpm -q sysaidon-prem 2>/dev/null
# Windows: pull the cumulative update that ships this fix.
Install-Module PSWindowsUpdate -Force -SkipPublisherCheck
Get-WindowsUpdate -AcceptAll -Install -AutoReboot
Verify the fix landed
# 1. Confirm the running version matches the fixed-in version from the advisory:
# https://documentation.sysaid.com/docs/24-40-60
# Use the platform-specific version probe above.
# 2. Re-scan with your vulnerability scanner (Nessus, Qualys, Tenable, OpenVAS).
# The scanner should no longer flag CVE-2025-2775 on the patched target.
# 3. Inspect recent service / kernel logs for crash loops or rollback events.
journalctl -u <service> --since "10 minutes ago"
dmesg --since "10 minutes ago"
If you cannot patch immediately
Disable XML external entity processing in the affected component if the vendor documents a configuration toggle. Otherwise, patch.
How to verify the fix worked
- After applying the patch, verify the running version in the product's admin UI or via the vendor-documented CLI command.
- Confirm the patched build matches the version listed in the vendor advisory.
- Run an authenticated vulnerability scan with a current signature set and confirm the scanner no longer flags CVE-2025-2775.
- Review logs for the entire pre-patch window for indicators of compromise listed in the vendor or CISA advisory.
- Confirm any network-layer mitigations that were applied as a stopgap have been reverted (or left in place intentionally) once the patch is verified.
If your installation was internet-reachable during the disclosure window, treat log review as part of the remediation rather than an optional follow-up. Look for unusually long URI paths containing traversal sequences, unexpectedly large responses from the affected endpoint, and outbound requests from the application to internal addresses or cloud-metadata endpoints. Treat any sensitive file the bug could disclose as exposed. Because SysAid On-Prem sits on CISA's Known Exploited Vulnerabilities catalog for this CVE, defenders should also pull the IOC list from the vendor advisory and from CISA's analysis if one was published.
Frequently asked questions
Is CVE-2025-2775 being exploited in the wild?
Yes. CISA added CVE-2025-2775 to the Known Exploited Vulnerabilities catalog, which means active exploitation has been confirmed by federal observation or credible vendor reporting.
Will a WAF or IDS rule fully mitigate CVE-2025-2775?
No. Network-layer filters can reduce noise and slow opportunistic scanners, but they will not stop a determined attacker. The vendor patch is the only durable fix.
How long should I plan for the upgrade?
Typical vendor-documented upgrade windows for SysAid On-Prem run from a few minutes to under an hour depending on cluster size. Test in a staging environment first and follow the vendor's documented HA upgrade order.
References
- Official vendor advisory: https://documentation.sysaid.com/docs/24-40-60
- NVD entry: https://nvd.nist.gov/vuln/detail/CVE-2025-2775
- CISA KEV catalog: https://www.cisa.gov/known-exploited-vulnerabilities-catalog
- Additional vendor or research reference: https://labs.watchtowr.com/sysowned-your-friendly-rce-support-ticket/
- Additional vendor or research reference: https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2025-2775
*This guide was assembled from the official vendor advisory, the NVD record, and the CISA KEV catalog entry on 2026-05-25. Always confirm against the vendor advisory before applying changes in production.*