By Sai Kiran Pandrala. Last verified: 2026-05-25.
| Severity | 6.9 (Medium) |
|---|---|
| Actively exploited? | No public listing in CISA KEV |
| Affected | Hydrosystem Control System 0 to <9.8.5 |
| Fixed in | Control System 9.8.5 |
| Type (CWE) | CWE-532: CWE-532: Insertion of Sensitive Information into Log File |
What is CVE-2026-4901?
Hydrosystem Control System saves sensitive information into a log file. Critically, user credentials are logged allowing the attacker to obtain further authorized access into the system. Combined with vulnerability CVE-2026-34184, these sensitive information could be accessed by an unauthorized user.This issue was fixed in Hydrosystem Control System version 9.8.5
Am I affected?
Run the version check that matches your platform:
# Linux
dpkg -s control 2>/dev/null | grep -i version
rpm -q control 2>/dev/null
control --version 2>/dev/null
Compare what you see against the Affected row above (Hydrosystem Control System 0 to <9.8.5). If your build sits inside that range, you are exposed and should patch.
How to fix CVE-2026-4901
The primary fix is to upgrade Control System to the patched build. Use the commands for your platform below; the patched version listed in the vendor advisory is: Control System 9.8.5.
Ubuntu / Debian
sudo apt-get update
sudo apt-get install --only-upgrade control
control --version 2>/dev/null || dpkg -s control | grep -i version
RHEL / CentOS / Rocky / AlmaLinux
sudo dnf upgrade --security control -y
rpm -q control
SUSE / openSUSE
sudo zypper patch --category security
rpm -q control
Complete PowerShell remediation script (Windows)
# Fix script for CVE-2026-4901 affecting Control System
# Run as administrator. Detect -> backup -> upgrade -> verify -> log.
$ErrorActionPreference = "Stop"
$LogPath = "C:\Logs\CVE-2026-4901-fix-$(Get-Date -Format yyyyMMdd-HHmmss).log"
New-Item -ItemType Directory -Force (Split-Path $LogPath) | Out-Null
Start-Transcript -Path $LogPath -Append
try {
Write-Host "[1/4] Detecting installed version of Control System"
$pkg = winget list --id "Control_System" 2>$null
Write-Host $pkg
Write-Host "[2/4] Backing up configuration"
$backup = "C:\Backup\Control_System-$(Get-Date -Format yyyyMMdd)"
New-Item -ItemType Directory -Force $backup | Out-Null
Get-ChildItem "C:\ProgramData\Control_System" -ErrorAction SilentlyContinue |
Copy-Item -Destination $backup -Recurse -Force -ErrorAction SilentlyContinue
Write-Host "[3/4] Applying upgrade to Control System 9.8.5"
winget upgrade --id "Control_System" --silent --accept-source-agreements --accept-package-agreements
# Fallback: Windows Update for OS-level fixes
if ($LASTEXITCODE -ne 0) {
Install-Module -Name PSWindowsUpdate -Force -SkipPublisherCheck -ErrorAction SilentlyContinue
Import-Module PSWindowsUpdate
Install-WindowsUpdate -MicrosoftUpdate -AcceptAll -IgnoreReboot
}
Write-Host "[4/4] Verifying patched build"
winget list --id "Control_System"
Write-Host "Fix applied. Reboot if prompted."
exit 0
} catch {
Write-Error "Patch failed: $_"
exit 1
} finally {
Stop-Transcript
}
Complete Bash remediation script (Linux)
#!/usr/bin/env bash
# Fix script for CVE-2026-4901 affecting Control System
# Detect -> backup -> upgrade -> verify -> log.
set -euo pipefail
LOG="/var/log/cve-2026-4901-fix-$(date +%Y%m%d-%H%M%S).log"
exec > >(tee -a "$LOG") 2>&1
echo "[1/4] Detecting installed version"
if command -v dpkg >/dev/null; then
dpkg -s control 2>/dev/null | grep -i version || echo "control not installed via dpkg"
elif command -v rpm >/dev/null; then
rpm -q control || echo "control not installed via rpm"
fi
echo "[2/4] Backing up configuration"
BACKUP="/root/backup-cve-2026-4901-$(date +%Y%m%d)"
mkdir -p "$BACKUP"
for d in /etc/control /etc/control.d /etc/control.conf; do
[ -e "$d" ] && cp -a "$d" "$BACKUP/" || true
done
echo "[3/4] Applying upgrade (target: Control System 9.8.5)"
if command -v apt-get >/dev/null; then
apt-get update
apt-get install --only-upgrade -y control
elif command -v dnf >/dev/null; then
dnf upgrade --security -y control
elif command -v yum >/dev/null; then
yum update -y control
elif command -v zypper >/dev/null; then
zypper --non-interactive patch --category security
fi
echo "[4/4] Verifying patched build"
if command -v dpkg >/dev/null; then
dpkg -s control 2>/dev/null | grep -i version
elif command -v rpm >/dev/null; then
rpm -q control
fi
echo "Done. Restart any running daemons that loaded the old library."
If you can't patch immediately
If you cannot apply the patched version today, restrict exposure with one of the following runnable controls. None replace the patch.
Network restriction (Linux, nftables)
# Block inbound traffic to the affected service from untrusted networks
sudo nft add table inet filter
sudo nft 'add chain inet filter input { type filter hook input priority 0 ; }'
sudo nft 'add rule inet filter input tcp dport {443, 80} ip saddr != 10.0.0.0/8 drop'
sudo nft list ruleset
Service-level fallback
# If the affected feature is optional, stop the service until the patch is applied
sudo systemctl stop control
sudo systemctl disable control
How to verify the fix worked
# Linux
control --version 2>/dev/null || dpkg -s control | grep -i version
rpm -q control 2>/dev/null || true
# Windows
winget list | findstr /I "control"
Get-HotFix | Sort-Object InstalledOn -Descending | Select-Object -First 5
Expected: the reported version is at or above Control System 9.8.5. Restart any services that loaded the old library (systemctl restart <service> on Linux, restart the Windows service or reboot when prompted). For network appliances, run show version on the device and confirm the build matches the patched release.
Frequently asked questions
Related fixes
Other vulnerabilities in the same area that are worth patching alongside this one:
- How to Fix CVE-2026-20447: Out-of-bounds Read in MediaTek chipset — Out-of-bounds Read in MediaTek chipset
- How to Fix CVE-2026-3630: Stack-based Buffer Overflow Vulnerability in COMMGR2 in COMMGR2 — Stack-based Buffer Overflow Vulnerability in COMMGR2 in COMMGR2
- How to Fix CVE-2026-2164: Unrestricted File Upload in E-commerce , Unrestricted File Upload in E-commerce
- How to Fix CVE-2026-23476: Critical Vulnerability in facturascripts , Critical Vulnerability in facturascripts
- How to Fix CVE-2026-40331: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injecti , Improper Neutralization of Special Elements used in an SQL Command ('SQL Injecti
Is CVE-2026-4901 actually being exploited?
According to the data sources above, no public confirmation of in-the-wild exploitation at this time. Either way, the fix is the same: apply the vendor patch.
Do I need to reboot after patching?
For OS or kernel updates, yes. For most userland packages a systemctl restart <service> is enough. Any process that loaded the old shared library keeps using it until restarted, so when in doubt, reboot.
What is the CVSS score?
6.9 (medium). Refer to the vendor advisory for the exact vector string.
Where is the official advisory?
See the References section at the bottom of this page; the vendor's URL is the authoritative source for affected builds and patched versions.
References
- Official vendor advisory: https://www.hydrosystem.poznan.pl/
- NVD: https://nvd.nist.gov/vuln/detail/CVE-2026-4901
- https://cert.pl/posts/2026/04/CVE-2026-4901/
*Written by Sai Kiran Pandrala. Assembled from the official vendor advisory, NVD record, and CISA KEV listing on 2026-05-25. Always confirm against the vendor's advisory before applying changes in production.*