Arista 7010T power supply failed: Diagnose & Fix
By Sai Kiran Pandrala · reviewed by Sai Kiran Pandrala, Editor Last verified: 2026-05-30
| Vendor | Arista |
|---|---|
| Operating system | Arista EOS |
| Category | Hardware Failure |
| Skill level | Intermediate to advanced |
| DIY-able? | Yes with CLI access; some scenarios need Arista TAC + RMA. |
A Arista platform behaving badly is usually one of three things: a thermal/PSU issue caught by `show environment all`, a transceiver problem caught by `show interfaces Ethernet1 detail`, or a boot-loader hang you only see on the console. Arista EOS surfaces all three differently from competitors, so the diagnostic order matters.
I will be honest: on the 7010T family I have seen at least one false-positive from the on-box monitoring per quarter. Always cross-check what `show version` and `show environment all` reports against the physical front-panel and a smell test of the chassis.
If this is your first Arista hardware issue, the good news is that Arista TAC is competent and the part-replacement RMA cycle is usually under a week for a covered unit.
What this guide covers
Diagnose and recover from power supply failed on a Arista 7010T.
Step-by-step
- Confirm which PSU failed.
- Verify the remaining PSU has enough capacity for the device + line cards + PoE budget.
- Note the failed PSU's part number.
- Replace during a maintenance window. most enterprise PSUs are hot-swappable.
- After replacement, confirm both PSUs show OK.
CLI / commands
# Verify hardware state
show version
show inventory
show environment all
# Collect for Arista TAC
show tech-support | redirect file:show-tech.log
When to RMA
- Repeated failure after re-seat and power-cycle
- Visible burn, scorching, or physical damage
- POST or memory diagnostic failure
- Hardware crashinfo without a software workaround
Frequently asked questions
Will this work on my specific Arista EOS version?
The procedure reflects current Arista EOS behaviour. Older releases may need minor syntax adjustments, use the CLI help (? or tab-completion) to verify.
Should I open a Arista TAC case immediately?
Open one if you suspect hardware failure or the symptom persists after a maintenance-window reload. Make sure your support entitlement is active first.
Where can I find the Arista official documentation?
https://www.arista.com/en/support/toi: search the product family + feature name.
Is this procedure safe in production?
Test in a lab or maintenance window first. Capture pre-change state so you can roll back.
Related guides
References
- Arista support portal: https://www.arista.com/en/support
- Arista knowledge base: https://www.arista.com/en/support/toi
- Arista security advisories: https://www.arista.com/en/support/advisories-notices
- Open a case: https://www.arista.com/en/support/customer-support
Reference material, not professional advice. Validate against your specific Arista EOS version and test in a non-production environment before applying.
Common patterns we see
When this symptom shows up on a Arista device, three patterns repeat:
1. Recent firmware update changed behavior, the symptom started within a week of an OTA push. Rollback or wait for the hotfix. 2. Environmental trigger. temperature, humidity, line voltage, network changes. Look at what changed in the environment. 3. Cumulative wear, components like batteries, gaskets, fans degrade over time. Replace the consumable rather than chasing a software fix.
Knowing which pattern applies saves time on the wrong fix.
Before you start
A few things to confirm so the Arista device fix goes cleanly:
- Latest firmware downloaded if you're going to update.
- Warranty + support contract status checked: opening sealed parts may void it.
- Backup of current configuration (where applicable) taken.
- Spare parts on hand if you anticipate replacement.
- Adequate workspace, lighting, and time, rushing causes regressions.
Quick verification
Before you walk away from a Arista device fix, run through:
1. Reproduce the original trigger. does the issue reappear? 2. Check the device's status / health screen for any new alerts. 3. Confirm paired devices (app, hub, controller) reconnected. 4. Save / commit any configuration changes per the device's normal workflow. 5. Note the change in your maintenance log with date + firmware version.
Escalation guide
For a Arista device, the right escalation depends on impact:
- Cosmetic / minor: log a ticket via the Arista app or web portal. Response 1-3 business days.
- Mid-impact: phone support. Have your serial number ready.
- Critical (production down, safety issue): in-person dealer / TAC visit. Bring proof of purchase.
- Out of warranty: third-party repair shop with manufacturer-certified technicians.
More frequently asked questions
Will this void my warranty?
Applying official firmware updates and following the user manual will not affect warranty. Opening sealed components, jumping safety circuits, or using third-party parts can void warranty in most jurisdictions.
Does this affect other devices on my network?
Generally no. The procedure is local to this device. Network-side changes (firmware updates that affect TLS, SMB, or routing) are flagged explicitly in the steps.
Is it safe to apply during business hours?
If the device is in production use, apply during a scheduled maintenance window. Most procedures need 2-15 minutes of downtime. Capture pre-change state so you can roll back if needed.
How often should I run preventive checks?
Quarterly for most consumer devices; monthly for production / commercial devices. Set a calendar reminder so the device stays healthy between issues.
Why is this happening on a brand-new unit?
Out-of-box defects do occur. If you've owned the device under 30 days and the symptom persists after a factory reset, escalate to the seller for replacement under DOA terms before opening a manufacturer support case.
Field notes from real incidents on Arista
When I work on Arista 7010T power supply failed: Diagnose & Fix the rhythm I lean on is the one I have built over years of these tickets, not a stack of generic advice. CloudVision Portal alerts are noisy unless you tune them; I disable the defaults and re-enable the ones that map to actual production events. EOS-API (eAPI) over HTTPS is the cleanest way to script Arista at scale; do not wrap CLI screen-scraping when eAPI returns JSON.
Show tech-support detail is the artifact Arista TAC expects on call one; bundle it with the agent logs before you open the ticket. Arista EOS lets you reload a module without reloading the chassis on most platforms, I use that capability more than people realise.
Tools I actually reach for
For Arista 7010T power supply failed: Diagnose & Fix on Arista the cheapest signal I can land usually comes from a known order of operations, not a kitchen-sink approach. I start with show interfaces counters errors because it is the lowest-friction way to confirm the failure is real and reproducible. If that returns ambiguous data, I escalate to show tech-support (capture for TAC), ping vrf <vrf> <target>, packet capture on the ingress interface (TAC will ask for it), and finally to show logging last 200 only when the cheaper tools cannot reach the layer the failure lives in. That ordering matches the failure surfaces I have actually seen on Arista units over the last few years, not an abstract taxonomy. The cheap signals gate the expensive ones so the investigation does not balloon into a multi-hour exercise.
Verification I run before I close the ticket
Before I mark Arista 7010T power supply failed: Diagnose & Fix resolved on a Arista unit, the verification loop below is what I actually run. Each step proves a different layer is green, and the order matters - the cheap checks gate the more expensive ones so I never burn an hour on a deep test that a shallow one would have failed in seconds.
show logging | include %LINK|%LINEPROTO|%BGP|%OSPFIf that one comes back clean, move to the next check. If it does not, stop and dig in there before layering more verification on top of a red signal.
show bgp summary # confirm session state after route changesIf that one comes back clean, move to the next check. If it does not, stop and dig in there before layering more verification on top of a red signal.
show interfaces <int> | include errors|drops|CRCIf that one comes back clean, move to the next check. If it does not, stop and dig in there before layering more verification on top of a red signal.
show spanning-tree summary # confirm topology stabilityIf that one comes back clean, move to the next check. If it does not, stop and dig in there before layering more verification on top of a red signal.
show ip route <prefix> # confirm best path post-changeOnly when every line above runs clean do I close the ticket and update the runbook with the timestamps. A green verification that nobody can reproduce is not a fix, it is luck waiting to regress.
Where I check first when the docs disagree
When two sources contradict each other on a Arista detail, the disambiguation order I lean on is stable across products and across years. github.com/aristanetworks for open-source tooling like Ansible roles is where I start for the ground-truth view. Arista TAC knowledge base is where I start for the ground-truth view. eos.arista.com for the official software documentation is where I start for the ground-truth view. Random blog posts and reseller wikis are signal, not ground truth, and I treat them as such until the references above either confirm or contradict the claim. The cost of trusting an unauthoritative source on Arista 7010T power supply failed: Diagnose & Fix is rarely worth the time it saved.
Pitfalls I have walked into on this exact path
The shortcuts that look smart on Arista 7010T power supply failed: Diagnose & Fix have a habit of biting back. The pitfalls below are the ones I have personally walked into on a Arista unit, not things I read about. Show tech-support detail is the artifact Arista TAC expects on call one; bundle it with the agent logs before you open the ticket. EOS-API (eAPI) over HTTPS is the cleanest way to script Arista at scale; do not wrap CLI screen-scraping when eAPI returns JSON. Arista EOS lets you reload a module without reloading the chassis on most platforms: I use that capability more than people realise. When in doubt I revert to the slower path that the manual prescribes - the time I save by skipping it is always smaller than the time I spend cleaning up afterwards.
What I tell the next on-call
When I hand Arista 7010T power supply failed: Diagnose & Fix off to the next person on rotation, the three lines I leave in the runbook are these. First, the symptom signature on Arista - not a paraphrase, the exact string that surfaces in logs or on the screen. Second, the diagnostic that gave the highest signal in the least time. Third, the exact verification command whose green output justified closing the ticket. That trio is what turns a one-off fix into a runbook entry the next engineer can use without paging me at three in the morning.
I also add a one-line note on the cost of getting this wrong. For Arista 7010T power supply failed: Diagnose & Fix on a Arista unit, the cost is rarely the replacement part or the patch itself. It is the downtime, the second site visit, and the trust deficit you spend with whoever owns the asset when the fix does not hold. That framing keeps the next on-call from choosing the cheap-looking shortcut that ends up costing the most in elapsed hours and goodwill.
Related fixes
Related guides worth a look while you sort this one out:
- Arista 7050X3 power supply failed: Diagnose & Fix
- Arista 7060X4 power supply failed: Diagnose & Fix
- Arista 7060X5 power supply failed: Diagnose & Fix
- Arista 7060X6 power supply failed: Diagnose & Fix
- Arista 7280R power supply failed: Diagnose & Fix
- Arista 7280R3 (routing role) power supply failed: Diagnose & Fix
People also ask
Will this work on my specific Arista EOS version?
The procedure reflects current Arista EOS behaviour. Older releases may need minor syntax adjustments, use the CLI help (`?` or tab-completion) to verify.
Should I open a Arista TAC case immediately?
Open one if you suspect hardware failure or the symptom persists after a maintenance-window reload. Make sure your support entitlement is active first.
Where can I find the Arista official documentation?
https://www.arista.com/en/support/toi. search the product family + feature name.
Is this procedure safe in production?
Test in a lab or maintenance window first. Capture pre-change state so you can roll back.