Arista 7060X4 all ports dead: Diagnose & Fix
By Sai Kiran Pandrala · reviewed by Sai Kiran Pandrala, Editor Last verified: 2026-05-30
| Vendor | Arista |
|---|---|
| Operating system | Arista EOS |
| Category | Hardware Failure |
| Skill level | Intermediate to advanced |
| DIY-able? | Yes with CLI access; some scenarios need Arista TAC + RMA. |
Treat this like a flight checklist. `show version` and `show environment all` on Arista EOS returns the data you need for a Arista Arista TAC case, if you have that saved before the box dies completely, your support call is 20 minutes shorter.
I have seen 7060X4 units that looked dead at the LED panel but were actually fine: the front panel had failed, not the data plane. Always verify with CLI before declaring time of death.
What follows is the recovery playbook, not the marketing version. Some steps assume a spare unit or a console cable; if you do not have them, the diagnostic section is still useful for the Arista TAC case.
What this guide covers
Diagnose and recover from all ports dead on a Arista 7060X4.
Repair sequence
- Try the same cable + endpoint on a known-good port to confirm the issue is the device.
- If modular, re-seat the affected line card.
- Check the platform / hardware status command.
- If a single line card is dead, RMA it. If the supervisor or chassis, RMA accordingly.
CLI / commands
# Verify hardware state
show version
show inventory
show environment all
# Collect for Arista TAC
show tech-support | redirect file:show-tech.log
When to RMA
- Repeated failure after re-seat and power-cycle
- Visible burn, scorching, or physical damage
- POST or memory diagnostic failure
- Hardware crashinfo without a software workaround
Frequently asked questions
Will this work on my specific Arista EOS version?
The procedure reflects current Arista EOS behaviour. Older releases may need minor syntax adjustments. use the CLI help (? or tab-completion) to verify.
Should I open a Arista TAC case immediately?
Open one if you suspect hardware failure or the symptom persists after a maintenance-window reload. Make sure your support entitlement is active first.
Where can I find the Arista official documentation?
https://www.arista.com/en/support/toi, search the product family + feature name.
Is this procedure safe in production?
Test in a lab or maintenance window first. Capture pre-change state so you can roll back.
Related guides
References
- Arista support portal: https://www.arista.com/en/support
- Arista knowledge base: https://www.arista.com/en/support/toi
- Arista security advisories: https://www.arista.com/en/support/advisories-notices
- Open a case: https://www.arista.com/en/support/customer-support
Reference material, not professional advice. Validate against your specific Arista EOS version and test in a non-production environment before applying.
Signal review
When this symptom shows up on a Arista device, three patterns repeat:
1. Recent firmware update changed behavior: the symptom started within a week of an OTA push. Rollback or wait for the hotfix. 2. Environmental trigger, temperature, humidity, line voltage, network changes. Look at what changed in the environment. 3. Cumulative wear. components like batteries, gaskets, fans degrade over time. Replace the consumable rather than chasing a software fix.
Knowing which pattern applies saves time on the wrong fix.
Cause analysis
A few things to confirm so the Arista device fix goes cleanly:
- Latest firmware downloaded if you're going to update.
- Warranty + support contract status checked, opening sealed parts may void it.
- Backup of current configuration (where applicable) taken.
- Spare parts on hand if you anticipate replacement.
- Adequate workspace, lighting, and time: rushing causes regressions.
Post-repair audit
On a Arista device, the test is rarely "reboot and see". Use this list:
- Active reproduction: trigger the original failure path on purpose.
- Indirect reproduction: do an activity that would expose the same subsystem.
- Status indicator review: every LED / display / app status should be green.
- 24-hour soak: leave the device under normal load overnight; check the next morning.
- Telemetry check: review the device or app's diagnostic log for new error entries.
When to call Arista support instead
Escalate if:
- The same symptom returns within 24 hours of a clean fix.
- You see physical damage (burn marks, swollen battery, cracked PCB).
- The device is in warranty and a hardware replacement is the cheaper outcome.
- Repair requires specialised tools you don't own (alignment jigs, calibration software).
- Following the official path keeps the warranty intact, which matters more than the time spent.
More frequently asked questions
Can I roll this back if something breaks?
Yes for software-level changes (firmware rollback, config rollback). Hardware changes are usually one-way. Always back up settings before starting.
Are there safer alternatives for non-technical users?
Yes, the manufacturer's self-service troubleshooter (HP Smart, LG ThinQ, Samsung Members, similar) usually walks through the same steps in a guided UI. Use that first if you're not comfortable with menu paths.
Should I update firmware first or last?
Update firmware first if a release note specifically mentions your symptom. Otherwise, finish the troubleshooting flow first, then update; that way you can isolate whether the update or the underlying fix solved it.
Will the procedure work on the international variant?
Some features and firmware paths are region-locked. Check the model spec sheet to confirm your variant supports the menu option referenced. If you're outside the US/EU, look for the regional support portal.
Does this affect other devices on my network?
Generally no. The procedure is local to this device. Network-side changes (firmware updates that affect TLS, SMB, or routing) are flagged explicitly in the steps.
Field notes from real incidents on Arista
When I work on Arista 7060X4 all ports dead: Diagnose & Fix the rhythm I lean on is the one I have built over years of these tickets. CloudVision Portal alerts are noisy unless you tune them; I disable the defaults and re-enable the ones that map to actual production events. Show tech-support detail is the artifact Arista TAC expects on call one; bundle it with the agent logs before you open the ticket. EOS-API (eAPI) over HTTPS is the cleanest way to script Arista at scale; do not wrap CLI screen-scraping when eAPI returns JSON.
Tools I actually reach for
For Arista 7060X4 all ports dead: Diagnose & Fix on Arista the cheapest signal I can land usually comes from a known order of operations, not a kitchen-sink approach. I start with show running-config | include <feature> because it is the lowest-friction way to confirm the failure is real and reproducible. If that returns ambiguous data, I escalate to show logging last 200, ping vrf <vrf> <target>, and finally to packet capture on the ingress interface (TAC will ask for it) only when the cheaper tools cannot reach the layer the failure lives in. That ordering matches the failure surfaces I have actually seen on Arista units over the last few years, not an abstract taxonomy. The cheap signals gate the expensive ones so the investigation does not balloon into a multi-hour exercise.
Verification I run before I close the ticket
Before I mark Arista 7060X4 all ports dead: Diagnose & Fix resolved on a Arista unit, the verification loop below is what I actually run. Each step proves a different layer is green, and the order matters - the cheap checks gate the more expensive ones so I never burn an hour on a deep test that a shallow one would have failed in seconds.
show interfaces <int> | include errors|drops|CRCIf that one comes back clean, move to the next check. If it does not, stop and dig in there before layering more verification on top of a red signal.
show logging | include %LINK|%LINEPROTO|%BGP|%OSPFIf that one comes back clean, move to the next check. If it does not, stop and dig in there before layering more verification on top of a red signal.
show ip route <prefix> # confirm best path post-changeOnly when every line above runs clean do I close the ticket and update the runbook with the timestamps. A green verification that nobody can reproduce is not a fix, it is luck waiting to regress.
Where I check first when the docs disagree
When two sources contradict each other on a Arista detail, the disambiguation order I lean on is stable across products and across years. github.com/aristanetworks for open-source tooling like Ansible roles is where I start for the ground-truth view. eos.arista.com for the official software documentation is where I start for the ground-truth view. arista.com/en/support/product-documentation for EOS command references is where I start for the ground-truth view. Random blog posts and reseller wikis are signal, not ground truth, and I treat them as such until the references above either confirm or contradict the claim. The cost of trusting an unauthoritative source on Arista 7060X4 all ports dead: Diagnose & Fix is rarely worth the time it saved.
Pitfalls I have walked into on this exact path
The shortcuts that look smart on Arista 7060X4 all ports dead: Diagnose & Fix have a habit of biting back. The pitfalls below are the ones I have personally walked into on a Arista unit, not things I read about. EOS-API (eAPI) over HTTPS is the cleanest way to script Arista at scale; do not wrap CLI screen-scraping when eAPI returns JSON. CloudVision Portal alerts are noisy unless you tune them; I disable the defaults and re-enable the ones that map to actual production events. When in doubt I revert to the slower path that the manual prescribes - the time I save by skipping it is always smaller than the time I spend cleaning up afterwards.
What I tell the next on-call
When I hand Arista 7060X4 all ports dead: Diagnose & Fix off to the next person on rotation, the three lines I leave in the runbook are these. First, the symptom signature on Arista - not a paraphrase, the exact string that surfaces in logs or on the screen. Second, the diagnostic that gave the highest signal in the least time. Third, the exact verification command whose green output justified closing the ticket. That trio is what turns a one-off fix into a runbook entry the next engineer can use without paging me at three in the morning.
I also add a one-line note on the cost of getting this wrong. For Arista 7060X4 all ports dead: Diagnose & Fix on a Arista unit, the cost is rarely the replacement part or the patch itself. It is the downtime, the second site visit, and the trust deficit you spend with whoever owns the asset when the fix does not hold. That framing keeps the next on-call from choosing the cheap-looking shortcut that ends up costing the most in elapsed hours and goodwill.
Related fixes
Related guides worth a look while you sort this one out:
- Arista 7010T all ports dead: Diagnose & Fix
- Arista 7050X3 all ports dead: Diagnose & Fix
- Arista 7060X5 all ports dead: Diagnose & Fix
- Arista 7060X6 all ports dead: Diagnose & Fix
- Arista 7280R all ports dead: Diagnose & Fix
- Arista 7280R3 (routing role) all ports dead: Diagnose & Fix
People also ask
Will this work on my specific Arista EOS version?
The procedure reflects current Arista EOS behaviour. Older releases may need minor syntax adjustments. use the CLI help (`?` or tab-completion) to verify.
Should I open a Arista TAC case immediately?
Open one if you suspect hardware failure or the symptom persists after a maintenance-window reload. Make sure your support entitlement is active first.
Where can I find the Arista official documentation?
https://www.arista.com/en/support/toi, search the product family + feature name.
Is this procedure safe in production?
Test in a lab or maintenance window first. Capture pre-change state so you can roll back.