Ciena 8700 Packetwave smoke smell or burned PCB: Diagnose & Fix
By Sai Kiran Pandrala · reviewed by Sai Kiran Pandrala, Editor Last verified: 2026-05-30
| Vendor | Ciena |
|---|---|
| Operating system | SAOS (Service-Aware OS) / Blue Planet |
| Category | Hardware Failure |
| Skill level | Intermediate to advanced |
| DIY-able? | Yes with CLI access; some scenarios need Ciena TAC + RMA. |
When a Ciena 8700 Packetwave starts misbehaving, the temptation is to reboot and hope. Resist it. Capture `software show` and `chassis show fans temperature` first; that 30-second buffer is the difference between a real root cause and another reload at 3am next week.
SAOS (Service-Aware OS) / Blue Planet has a habit of logging the actual failing component into the system log seconds before the LED transitions. Tail the log while you run the diagnostic commands. you will often see the answer scroll past in real time.
Below is the exact sequence I run on customer gear. Steps are ordered cheapest-first so you exit early if it really is just a loose cable.
What this guide covers
Diagnose and recover from smoke smell or burned PCB on a Ciena 8700 Packetwave.
Resolve
- STOP. Power off the device at the wall before touching it.
- Open the chassis and identify which board / module is the source of the smell.
- Photograph the visible damage (scorched capacitors, blackened ICs).
- Note the device serial number and exact model for the support case.
- Do not power back on, burned components fail closed and can damage adjacent boards.
- Open a Ciena TAC case with the photos and serial.
- RMA the affected component (line card, supervisor, PSU) or the full chassis if the backplane is damaged.
CLI / commands
# Verify hardware state
software show
chassis show inventory
chassis show fans temperature
# Collect for Ciena TAC
show diagnostics
When to RMA
- Repeated failure after re-seat and power-cycle
- Visible burn, scorching, or physical damage
- POST or memory diagnostic failure
- Hardware crashinfo without a software workaround
Frequently asked questions
Will this work on my specific SAOS (Service-Aware OS) / Blue Planet version?
The procedure reflects current SAOS (Service-Aware OS) / Blue Planet behaviour. Older releases may need minor syntax adjustments: use the CLI help (? or tab-completion) to verify.
Should I open a Ciena TAC case immediately?
Open one if you suspect hardware failure or the symptom persists after a maintenance-window reload. Make sure your support entitlement is active first.
Where can I find the Ciena official documentation?
https://www.ciena.com/insights/knowledge-base, search the product family + feature name.
Is this procedure safe in production?
Test in a lab or maintenance window first. Capture pre-change state so you can roll back.
Related guides
References
- Ciena support portal: https://www.ciena.com/services/support/
- Ciena knowledge base: https://www.ciena.com/insights/knowledge-base
- Ciena security advisories: https://www.ciena.com/services/support/security-advisories
- Open a case: https://www.ciena.com/services/support/contact-support
Reference material, not professional advice. Validate against your specific SAOS (Service-Aware OS) / Blue Planet version and test in a non-production environment before applying.
What changed recently?
Fault diagnosis on a Ciena device goes faster when you map the symptom to a recent change:
- Did firmware update in the last 7 days?
- Did the network (router, ISP, VPN) change?
- Was the device moved physically?
- Did paired devices (phone, hub, app) update?
- Were any accessories swapped in or out?
The answer narrows the root cause to a manageable subset.
Safety + preconditions
Before any work on a Ciena device:
- Unplug from mains for any internal-access procedure.
- Discharge stored energy (capacitors in PSUs, residual battery charge) per manufacturer guidance.
- Use ESD-safe handling for boards and modules. no carpet, no wool sleeves.
- Avoid moisture; never apply liquids near vents or connectors.
- If you smell smoke, see scorch marks, or feel uneven heat, stop and escalate.
Validate
After applying the fix on your Ciena device, confirm:
- The original symptom is no longer reproducible.
- Related features (status LEDs, app sync, paired accessories) still work.
- The device responds to a soft reboot without the fault returning.
- Any error codes that were on display have cleared.
- Documentation (your service log, the brand companion app) reflects the change.
When to call Ciena support instead
Escalate if:
- The same symptom returns within 24 hours of a clean fix.
- You see physical damage (burn marks, swollen battery, cracked PCB).
- The device is in warranty and a hardware replacement is the cheaper outcome.
- Repair requires specialised tools you don't own (alignment jigs, calibration software).
- Following the official path keeps the warranty intact, which matters more than the time spent.
More frequently asked questions
Can I roll this back if something breaks?
Yes for software-level changes (firmware rollback, config rollback). Hardware changes are usually one-way. Always back up settings before starting.
Will this void my warranty?
Applying official firmware updates and following the user manual will not affect warranty. Opening sealed components, jumping safety circuits, or using third-party parts can void warranty in most jurisdictions.
Does this affect other devices on my network?
Generally no. The procedure is local to this device. Network-side changes (firmware updates that affect TLS, SMB, or routing) are flagged explicitly in the steps.
What if the fix returns after a reboot?
Persistent fault returns mean either: a hardware fault (escalate), a configuration that's being overwritten by a sync source (check cloud profiles), or a regression in a recent firmware update (rollback).
How long does this fix usually take?
Most users complete the steps in 20-45 minutes the first time, and 5-10 minutes on subsequent runs once the menu paths are familiar.
Field notes from real incidents on Ciena
When I work on Ciena 8700 Packetwave smoke smell or burned PCB: Diagnose & Fix the rhythm I lean on is the one I have built over years of these tickets. Show tech-support is the artifact TAC will ask for first, capture it before you change anything so the pre-change state is preserved. I never push a config change without a rollback timer; commit confirmed on Junos, archive on IOS, or a scripted timeout on EOS. Most spanning-tree storms I have walked into started with a user-side switch that nobody documented; topology audits pay off the day the loop forms.
Tools I actually reach for
For Ciena 8700 Packetwave smoke smell or burned PCB: Diagnose & Fix on Ciena the cheapest signal I can land usually comes from a known order of operations, not a kitchen-sink approach. I start with show tech-support (capture for TAC) because it is the lowest-friction way to confirm the failure is real and reproducible. If that returns ambiguous data, I escalate to show platform hardware capacity, show interfaces counters errors, show logging last 200, traceroute vrf <vrf> <target>, and finally to packet capture on the ingress interface (TAC will ask for it) only when the cheaper tools cannot reach the layer the failure lives in. That ordering matches the failure surfaces I have actually seen on Ciena units over the last few years, not an abstract taxonomy. The cheap signals gate the expensive ones so the investigation does not balloon into a multi-hour exercise.
Verification I run before I close the ticket
Before I mark Ciena 8700 Packetwave smoke smell or burned PCB: Diagnose & Fix resolved on a Ciena unit, the verification loop below is what I actually run. Each step proves a different layer is green, and the order matters - the cheap checks gate the more expensive ones so I never burn an hour on a deep test that a shallow one would have failed in seconds.
show interfaces <int> | include errors|drops|CRCIf that one comes back clean, move to the next check. If it does not, stop and dig in there before layering more verification on top of a red signal.
show logging | include %LINK|%LINEPROTO|%BGP|%OSPFIf that one comes back clean, move to the next check. If it does not, stop and dig in there before layering more verification on top of a red signal.
show ip route <prefix> # confirm best path post-changeOnly when every line above runs clean do I close the ticket and update the runbook with the timestamps. A green verification that nobody can reproduce is not a fix, it is luck waiting to regress.
Where I check first when the docs disagree
When two sources contradict each other on a Ciena detail, the disambiguation order I lean on is stable across products and across years. vendor release notes for the running software version is where I start for the ground-truth view. vendor official command reference (Cisco DocCD, Arista EOS Central, Juniper TechLibrary, etc.) is where I start for the ground-truth view. RFCs for the protocol in question (rfc-editor.org) is where I start for the ground-truth view. vendor TAC knowledge base is where I start for the ground-truth view. Random blog posts and reseller wikis are signal, not ground truth, and I treat them as such until the references above either confirm or contradict the claim. The cost of trusting an unauthoritative source on Ciena 8700 Packetwave smoke smell or burned PCB: Diagnose & Fix is rarely worth the time it saved.
Pitfalls I have walked into on this exact path
The shortcuts that look smart on Ciena 8700 Packetwave smoke smell or burned PCB: Diagnose & Fix have a habit of biting back. The pitfalls below are the ones I have personally walked into on a Ciena unit, not things I read about. Half the BGP weirdness I have triaged was a route-map that someone copied from a template without reading what it actually filtered. I never push a config change without a rollback timer; commit confirmed on Junos, archive on IOS, or a scripted timeout on EOS. Counters lie if you do not clear them; clear counters, reproduce, and read the deltas, not the cumulative numbers. When in doubt I revert to the slower path that the manual prescribes - the time I save by skipping it is always smaller than the time I spend cleaning up afterwards.
What I tell the next on-call
When I hand Ciena 8700 Packetwave smoke smell or burned PCB: Diagnose & Fix off to the next person on rotation, the three lines I leave in the runbook are these. First, the symptom signature on Ciena - not a paraphrase, the exact string that surfaces in logs or on the screen. Second, the diagnostic that gave the highest signal in the least time. Third, the exact verification command whose green output justified closing the ticket. That trio is what turns a one-off fix into a runbook entry the next engineer can use without paging me at three in the morning.
I also add a one-line note on the cost of getting this wrong. For Ciena 8700 Packetwave smoke smell or burned PCB: Diagnose & Fix on a Ciena unit, the cost is rarely the replacement part or the patch itself. It is the downtime, the second site visit, and the trust deficit you spend with whoever owns the asset when the fix does not hold. That framing keeps the next on-call from choosing the cheap-looking shortcut that ends up costing the most in elapsed hours and goodwill.
Related fixes
Related guides worth a look while you sort this one out:
- Ciena 5170 Service Aggregation smoke smell or burned PCB: Diagnose & Fix
- Ciena 5171 Service Aggregation Service Edge smoke smell or burned PCB: Diagnose & Fix
- Ciena 6500 Packet-Optical smoke smell or burned PCB: Diagnose & Fix
- Ciena 8700 Packetwave all ports dead: Diagnose & Fix
- Ciena 8700 Packetwave: How to back up configs nightly to a Git repo
- Ciena 8700 Packetwave: How to deploy with a Python script (paramiko / netmiko / native API)
People also ask
Will this work on my specific SAOS (Service-Aware OS) / Blue Planet version?
The procedure reflects current SAOS (Service-Aware OS) / Blue Planet behaviour. Older releases may need minor syntax adjustments: use the CLI help (`?` or tab-completion) to verify.
Should I open a Ciena TAC case immediately?
Open one if you suspect hardware failure or the symptom persists after a maintenance-window reload. Make sure your support entitlement is active first.
Where can I find the Ciena official documentation?
https://www.ciena.com/insights/knowledge-base, search the product family + feature name.
Is this procedure safe in production?
Test in a lab or maintenance window first. Capture pre-change state so you can roll back.