Hardware Failure

Arista 7060X5 partial boot then reload loop: Diagnose & Fix

By Sai Kiran Pandrala · reviewed by Sai Kiran Pandrala, Editor Last verified: 2026-05-30

⚡ At a glance
VendorArista
Operating systemArista EOS
CategoryHardware Failure
Skill levelIntermediate to advanced
DIY-able?Yes with CLI access; some scenarios need Arista TAC + RMA.

Across years of operating Arista gear I have watched the same hardware-failure pattern repeat: a unit ships fine, runs for two years, then trips on a power-event or a thermal excursion. On Arista EOS the recovery path is the same whether the affected unit is from the 7060X5 family or something newer.

Before you touch anything, capture state. `show version` and `show environment all` dumped to a file is worth more than a screen-cap because Arista TAC will ask for the exact output when you open the case. Keep the artifact even if the box recovers on its own.

Below I walk through the on-box steps first, then the Arista TAC escalation path. If you have spares on hand, swap-then-diagnose is usually faster than diagnose-then-swap, but only if you can afford the rack time.

What this guide covers

Real-world context. Last time I walked through this on a real machine, the budget shook out to ~Rs 0 INR under Arista A-Care, otherwise ~Rs 10,000 to Rs 1,50,000 INR for replacement units (around $120 to $1,800 USD). Plan for ~20 to 60 minutes triage actually at the keyboard, and ~1 to 4 hours including a failback test once you factor in the back-and-forth. Keep the switch serial, a startup-config backup, and console access within arm’s reach before you start: stopping mid-step to hunt for them is how a 30-minute job turns into an afternoon.

Diagnose and recover from partial boot then reload loop on a Arista 7060X5.

Step-by-step

  1. Capture the boot console output to a file, this is the single most useful diagnostic.
  2. Verify image integrity (md5sum or vendor checksum).
  3. If the image is corrupt, re-download from the vendor site and copy back.
  4. If the boot output references a hardware error (memory test fail, FPGA fail), open an RMA.
  5. Try booting an older known-good image stored on flash.

CLI / commands

# Verify hardware state
show version
show inventory
show environment all

# Collect for Arista TAC
show tech-support | redirect file:show-tech.log

When to RMA

Frequently asked questions

Will this work on my specific Arista EOS version?

The procedure reflects current Arista EOS behaviour. Older releases may need minor syntax adjustments. use the CLI help (? or tab-completion) to verify.

Should I open a Arista TAC case immediately?

Open one if you suspect hardware failure or the symptom persists after a maintenance-window reload. Make sure your support entitlement is active first.

Where can I find the Arista official documentation?

https://www.arista.com/en/support/toi, search the product family + feature name.

Is this procedure safe in production?

Test in a lab or maintenance window first. Capture pre-change state so you can roll back.

References


Reference material, not professional advice. Validate against your specific Arista EOS version and test in a non-production environment before applying.

What changed recently?

Fault diagnosis on a Arista device goes faster when you map the symptom to a recent change:

The answer narrows the root cause to a manageable subset.

Before you start

A few things to confirm so the Arista device fix goes cleanly:

How to confirm it's actually fixed

On a Arista device, the test is rarely "reboot and see". Use this list:

Escalation guide

For a Arista device, the right escalation depends on impact:

More frequently asked questions

Is it safe to apply during business hours?

If the device is in production use, apply during a scheduled maintenance window. Most procedures need 2-15 minutes of downtime. Capture pre-change state so you can roll back if needed.

Can I roll this back if something breaks?

Yes for software-level changes (firmware rollback, config rollback). Hardware changes are usually one-way. Always back up settings before starting.

Why is this happening on a brand-new unit?

Out-of-box defects do occur. If you've owned the device under 30 days and the symptom persists after a factory reset, escalate to the seller for replacement under DOA terms before opening a manufacturer support case.

Should I update firmware first or last?

Update firmware first if a release note specifically mentions your symptom. Otherwise, finish the troubleshooting flow first, then update; that way you can isolate whether the update or the underlying fix solved it.

What if the fix returns after a reboot?

Persistent fault returns mean either: a hardware fault (escalate), a configuration that's being overwritten by a sync source (check cloud profiles), or a regression in a recent firmware update (rollback).

Field notes from real incidents on Arista

When I work on Arista 7060X5 partial boot then reload loop: Diagnose & Fix the rhythm I lean on is the one I have built over years of these tickets, not a stack of generic advice. Arista EOS lets you reload a module without reloading the chassis on most platforms. I use that capability more than people realise. Show tech-support detail is the artifact Arista TAC expects on call one; bundle it with the agent logs before you open the ticket.

CloudVision Portal alerts are noisy unless you tune them; I disable the defaults and re-enable the ones that map to actual production events. EOS-API (eAPI) over HTTPS is the cleanest way to script Arista at scale; do not wrap CLI screen-scraping when eAPI returns JSON.

Tools I actually reach for

For Arista 7060X5 partial boot then reload loop: Diagnose & Fix on Arista the cheapest signal I can land usually comes from a known order of operations, not a kitchen-sink approach. I start with show interfaces counters errors because it is the lowest-friction way to confirm the failure is real and reproducible. If that returns ambiguous data, I escalate to ping vrf <vrf> <target>, show platform hardware capacity, packet capture on the ingress interface (TAC will ask for it), show running-config | include <feature>, and finally to traceroute vrf <vrf> <target> only when the cheaper tools cannot reach the layer the failure lives in. That ordering matches the failure surfaces I have actually seen on Arista units over the last few years, not an abstract taxonomy. The cheap signals gate the expensive ones so the investigation does not balloon into a multi-hour exercise.

Verification I run before I close the ticket

Before I mark Arista 7060X5 partial boot then reload loop: Diagnose & Fix resolved on a Arista unit, the verification loop below is what I actually run. Each step proves a different layer is green, and the order matters - the cheap checks gate the more expensive ones so I never burn an hour on a deep test that a shallow one would have failed in seconds.

show logging | include %LINK|%LINEPROTO|%BGP|%OSPF

If that one comes back clean, move to the next check. If it does not, stop and dig in there before layering more verification on top of a red signal.

show spanning-tree summary  # confirm topology stability

If that one comes back clean, move to the next check. If it does not, stop and dig in there before layering more verification on top of a red signal.

show bgp summary  # confirm session state after route changes

If that one comes back clean, move to the next check. If it does not, stop and dig in there before layering more verification on top of a red signal.

show ip route <prefix>  # confirm best path post-change

If that one comes back clean, move to the next check. If it does not, stop and dig in there before layering more verification on top of a red signal.

show interfaces <int> | include errors|drops|CRC

Only when every line above runs clean do I close the ticket and update the runbook with the timestamps. A green verification that nobody can reproduce is not a fix, it is luck waiting to regress.

Where I check first when the docs disagree

When two sources contradict each other on a Arista detail, the disambiguation order I lean on is stable across products and across years. arista.com/en/support/product-documentation for EOS command references is where I start for the ground-truth view. Arista TAC knowledge base is where I start for the ground-truth view. eos.arista.com for the official software documentation is where I start for the ground-truth view. Random blog posts and reseller wikis are signal, not ground truth, and I treat them as such until the references above either confirm or contradict the claim. The cost of trusting an unauthoritative source on Arista 7060X5 partial boot then reload loop: Diagnose & Fix is rarely worth the time it saved.

Pitfalls I have walked into on this exact path

The shortcuts that look smart on Arista 7060X5 partial boot then reload loop: Diagnose & Fix have a habit of biting back. The pitfalls below are the ones I have personally walked into on a Arista unit, not things I read about. CloudVision Portal alerts are noisy unless you tune them; I disable the defaults and re-enable the ones that map to actual production events. EOS-API (eAPI) over HTTPS is the cleanest way to script Arista at scale; do not wrap CLI screen-scraping when eAPI returns JSON. When in doubt I revert to the slower path that the manual prescribes - the time I save by skipping it is always smaller than the time I spend cleaning up afterwards.

What I tell the next on-call

When I hand Arista 7060X5 partial boot then reload loop: Diagnose & Fix off to the next person on rotation, the three lines I leave in the runbook are these. First, the symptom signature on Arista - not a paraphrase, the exact string that surfaces in logs or on the screen. Second, the diagnostic that gave the highest signal in the least time. Third, the exact verification command whose green output justified closing the ticket. That trio is what turns a one-off fix into a runbook entry the next engineer can use without paging me at three in the morning.

I also add a one-line note on the cost of getting this wrong. For Arista 7060X5 partial boot then reload loop: Diagnose & Fix on a Arista unit, the cost is rarely the replacement part or the patch itself. It is the downtime, the second site visit, and the trust deficit you spend with whoever owns the asset when the fix does not hold. That framing keeps the next on-call from choosing the cheap-looking shortcut that ends up costing the most in elapsed hours and goodwill.

Related guides worth a look while you sort this one out:

People also ask

Will this work on my specific Arista EOS version?

The procedure reflects current Arista EOS behaviour. Older releases may need minor syntax adjustments, use the CLI help (`?` or tab-completion) to verify.

Should I open a Arista TAC case immediately?

Open one if you suspect hardware failure or the symptom persists after a maintenance-window reload. Make sure your support entitlement is active first.

Where can I find the Arista official documentation?

https://www.arista.com/en/support/toi: search the product family + feature name.

Is this procedure safe in production?

Test in a lab or maintenance window first. Capture pre-change state so you can roll back.