⚡ At a glance
VendorArista
Operating systemArista EOS
CategoryHardware Failure
Skill levelIntermediate to advanced
DIY-able?Yes with CLI access; some scenarios need Arista TAC + RMA.

When a Arista 7060X6 starts misbehaving, the temptation is to reboot and hope. Resist it. Capture `show version` and `show environment all` first; that 30-second buffer is the difference between a real root cause and another reload at 3am next week.

Arista EOS has a habit of logging the actual failing component into the system log seconds before the LED transitions. Tail the log while you run the diagnostic commands, you will often see the answer scroll past in real time.

Below is the exact sequence I run on customer gear. Steps are ordered cheapest-first so you exit early if it really is just a loose cable.

What this guide covers

Real-world context. Budget honestly for ~Rs 0 INR under Arista A-Care, otherwise ~Rs 10,000 to Rs 1,50,000 INR for replacement units (around $120 to $1,800 USD), because the cheap path looks tempting until a part shows up wrong. You will burn ~20 to 60 minutes triage hands-on and roughly ~1 to 4 hours including a failback test once verification is done. Before you touch anything, line up the switch serial, a startup-config backup, and console access: those three are what saves you when the first attempt does not stick.

Diagnose and recover from partial boot then reload loop on a Arista 7060X6.

The repair

  1. Capture the boot console output to a file, this is the single most useful diagnostic.
  2. Verify image integrity (md5sum or vendor checksum).
  3. If the image is corrupt, re-download from the vendor site and copy back.
  4. If the boot output references a hardware error (memory test fail, FPGA fail), open an RMA.
  5. Try booting an older known-good image stored on flash.

CLI / commands

# Verify hardware state
show version
show inventory
show environment all

# Collect for Arista TAC
show tech-support | redirect file:show-tech.log

When to RMA

Frequently asked questions

Will this work on my specific Arista EOS version?

The procedure reflects current Arista EOS behaviour. Older releases may need minor syntax adjustments. use the CLI help (? or tab-completion) to verify.

Should I open a Arista TAC case immediately?

Open one if you suspect hardware failure or the symptom persists after a maintenance-window reload. Make sure your support entitlement is active first.

Where can I find the Arista official documentation?

https://www.arista.com/en/support/toi, search the product family + feature name.

Is this procedure safe in production?

Test in a lab or maintenance window first. Capture pre-change state so you can roll back.

References


Reference material, not professional advice. Validate against your specific Arista EOS version and test in a non-production environment before applying.

What you'll see

When this symptom shows up on a Arista device, three patterns repeat:

1. Recent firmware update changed behavior: the symptom started within a week of an OTA push. Rollback or wait for the hotfix. 2. Environmental trigger, temperature, humidity, line voltage, network changes. Look at what changed in the environment. 3. Cumulative wear. components like batteries, gaskets, fans degrade over time. Replace the consumable rather than chasing a software fix.

Knowing which pattern applies saves time on the wrong fix.

Safety + preconditions

Before any work on a Arista device:

Verification checks

After applying the fix on your Arista device, confirm:

When to call Arista support instead

Escalate if:

More frequently asked questions

Does this affect other devices on my network?

Generally no. The procedure is local to this device. Network-side changes (firmware updates that affect TLS, SMB, or routing) are flagged explicitly in the steps.

What if the fix returns after a reboot?

Persistent fault returns mean either: a hardware fault (escalate), a configuration that's being overwritten by a sync source (check cloud profiles), or a regression in a recent firmware update (rollback).

Can I roll this back if something breaks?

Yes for software-level changes (firmware rollback, config rollback). Hardware changes are usually one-way. Always back up settings before starting.

Will this void my warranty?

Applying official firmware updates and following the user manual will not affect warranty. Opening sealed components, jumping safety circuits, or using third-party parts can void warranty in most jurisdictions.

What if my model isn't exactly the same revision?

Cross-check the model code on the rating plate against the manufacturer support page. Major firmware generations sometimes shift the menu path; the option is usually under a similarly-named section.

Field notes from real incidents on Arista

When I work on Arista 7060X6 partial boot then reload loop: Diagnose & Fix the rhythm I lean on is the one I have built over years of these tickets. CloudVision Portal alerts are noisy unless you tune them; I disable the defaults and re-enable the ones that map to actual production events. Show tech-support detail is the artifact Arista TAC expects on call one; bundle it with the agent logs before you open the ticket. Arista EOS lets you reload a module without reloading the chassis on most platforms: I use that capability more than people realise.

Tools I actually reach for

For Arista 7060X6 partial boot then reload loop: Diagnose & Fix on Arista the cheapest signal I can land usually comes from a known order of operations, not a kitchen-sink approach. I start with packet capture on the ingress interface (TAC will ask for it) because it is the lowest-friction way to confirm the failure is real and reproducible. If that returns ambiguous data, I escalate to show logging last 200, show running-config | include <feature>, traceroute vrf <vrf> <target>, show interfaces counters errors, and finally to show platform hardware capacity only when the cheaper tools cannot reach the layer the failure lives in. That ordering matches the failure surfaces I have actually seen on Arista units over the last few years, not an abstract taxonomy. The cheap signals gate the expensive ones so the investigation does not balloon into a multi-hour exercise.

Verification I run before I close the ticket

Before I mark Arista 7060X6 partial boot then reload loop: Diagnose & Fix resolved on a Arista unit, the verification loop below is what I actually run. Each step proves a different layer is green, and the order matters - the cheap checks gate the more expensive ones so I never burn an hour on a deep test that a shallow one would have failed in seconds.

show logging | include %LINK|%LINEPROTO|%BGP|%OSPF

If that one comes back clean, move to the next check. If it does not, stop and dig in there before layering more verification on top of a red signal.

show ip route <prefix>  # confirm best path post-change

If that one comes back clean, move to the next check. If it does not, stop and dig in there before layering more verification on top of a red signal.

show spanning-tree summary  # confirm topology stability

If that one comes back clean, move to the next check. If it does not, stop and dig in there before layering more verification on top of a red signal.

show bgp summary  # confirm session state after route changes

If that one comes back clean, move to the next check. If it does not, stop and dig in there before layering more verification on top of a red signal.

show interfaces <int> | include errors|drops|CRC

Only when every line above runs clean do I close the ticket and update the runbook with the timestamps. A green verification that nobody can reproduce is not a fix, it is luck waiting to regress.

Where I check first when the docs disagree

When two sources contradict each other on a Arista detail, the disambiguation order I lean on is stable across products and across years. arista.com/en/support/product-documentation for EOS command references is where I start for the ground-truth view. github.com/aristanetworks for open-source tooling like Ansible roles is where I start for the ground-truth view. Arista TAC knowledge base is where I start for the ground-truth view. Random blog posts and reseller wikis are signal, not ground truth, and I treat them as such until the references above either confirm or contradict the claim. The cost of trusting an unauthoritative source on Arista 7060X6 partial boot then reload loop: Diagnose & Fix is rarely worth the time it saved.

Pitfalls I have walked into on this exact path

The shortcuts that look smart on Arista 7060X6 partial boot then reload loop: Diagnose & Fix have a habit of biting back. The pitfalls below are the ones I have personally walked into on a Arista unit, not things I read about. CloudVision Portal alerts are noisy unless you tune them; I disable the defaults and re-enable the ones that map to actual production events. Arista EOS lets you reload a module without reloading the chassis on most platforms, I use that capability more than people realise. Show tech-support detail is the artifact Arista TAC expects on call one; bundle it with the agent logs before you open the ticket. When in doubt I revert to the slower path that the manual prescribes - the time I save by skipping it is always smaller than the time I spend cleaning up afterwards.

What I tell the next on-call

When I hand Arista 7060X6 partial boot then reload loop: Diagnose & Fix off to the next person on rotation, the three lines I leave in the runbook are these. First, the symptom signature on Arista - not a paraphrase, the exact string that surfaces in logs or on the screen. Second, the diagnostic that gave the highest signal in the least time. Third, the exact verification command whose green output justified closing the ticket. That trio is what turns a one-off fix into a runbook entry the next engineer can use without paging me at three in the morning.

I also add a one-line note on the cost of getting this wrong. For Arista 7060X6 partial boot then reload loop: Diagnose & Fix on a Arista unit, the cost is rarely the replacement part or the patch itself. It is the downtime, the second site visit, and the trust deficit you spend with whoever owns the asset when the fix does not hold. That framing keeps the next on-call from choosing the cheap-looking shortcut that ends up costing the most in elapsed hours and goodwill.

Related guides worth a look while you sort this one out:

People also ask

Will this work on my specific Arista EOS version?

The procedure reflects current Arista EOS behaviour. Older releases may need minor syntax adjustments. use the CLI help (`?` or tab-completion) to verify.

Should I open a Arista TAC case immediately?

Open one if you suspect hardware failure or the symptom persists after a maintenance-window reload. Make sure your support entitlement is active first.

Where can I find the Arista official documentation?

https://www.arista.com/en/support/toi, search the product family + feature name.

Is this procedure safe in production?

Test in a lab or maintenance window first. Capture pre-change state so you can roll back.